Model: TD100SD |
Prime power |
kVA |
100 |
Standby power |
kVA |
110 |
Rated voltage line to line |
V |
400/230 |
Rated current |
A |
152 |
Maximum sound level |
dB(@7m) |
96 |
Engine- SDEC |
Model |
|
4HTAA4.3-G21 |
Aspiration |
Turbocharged, aftercooler |
Fuel system |
Longkou in-line “P” type |
No. cylinders |
|
4 in line |
Displacement |
L |
4.3 |
Bore*Stroke |
mm |
105*124 |
Compression ratio |
|
16:1 |
Rated speed |
r/min |
1500 |
Rated net power(with fan) |
Kw |
95 |
Governor type |
|
Electronic |
Start Motor |
V |
24 |
Exhaust System |
Exhaust gas flow |
m3/min |
16.1 |
Exhaust gas temperature |
℃ |
600 |
Max. pressure |
kPa |
8 |
Aspiration System |
Max inlet pressure |
kPa |
6 |
Combustion volume |
m³/min |
/ |
Air flow |
m3/min |
6.8 |
Fuel System |
100% load(Prime power) |
L/h |
23 |
75% load(Prime power) |
L/h |
17.1 |
50% load(Prime power) |
L/h |
11.8 |
Fuel tank capacity |
L |
185 |
Lubrication System |
Oil capacity |
L |
13 |
Lub. Method |
Fully forced pressure feed |
Oil pump |
Gear type driven by camshaft |
Cooling System |
Water capacity(engine only) |
L |
6.8 |
Thermostat operation range |
℃ |
82-95 |
Max water temperature |
℃ |
104 |
Alternator |
Model |
Technic |
TP274C |
Phase |
|
3 |
Voltage |
V |
400/230 |
Wiring Type |
|
3 Phase 4 wire, Y type |
Bearing |
|
1 |
Power factor |
|
0.8 |
Frequency |
Hz |
50 |
Prime power |
kW |
80 |
Exciter Type |
|
Brushless, self-excitation |
Voltage regulation |
% |
±0.5 |
Protection Grade |
|
IP 23 |
Insulation grade |
|
H/H |
Altitude |
m |
≤1000 |
Controller |
Model |
Deepsea |
DSE6120 |
Protective functions: |
˃ Low oil pressure |
˃ High water temperature |
˃ High/low voltage |
˃ High Engine Temperature and Overspeed. |
˃ Voltage regulator frequency regulator |
˃ Emergency stop |
˃ Start failure |